| Nov 11 |
Class II |
Baxter Healthcare Corporation Device |
TruSystem 7500 Hybrid Plus (FC), Fixed-Installation Operating Table Column, Model/Catalog Number: 1854087 There is an issue with the main lift mechanism. The main lift may unexpectedly drop from its set position to its lowest position during use. In these cases, the tabletop could not be raised again after the drop occurred. The issue has been associated with unexpected wear of the main lift assembly, also known as the telescopic spindle. An uncontrolled drop of the surgical table may result in an abrupt patient displacement during surgery. Serious or critical adverse health consequences may occur, including traumatic injury, airway compromise, and surgical procedure complications, among others. Baxter has received three complaints related to this issue, with no reported patient injury. |
| Nov 11 |
Class II |
Baxter Healthcare Corporation Device |
Operating Table TruSystem 7000 U (dV), Model/Catalog Number: 1723633 There is an issue with the main lift mechanism. The main lift may unexpectedly drop from its set position to its lowest position during use. In these cases, the tabletop could not be raised again after the drop occurred. The issue has been associated with unexpected wear of the main lift assembly, also known as the telescopic spindle. An uncontrolled drop of the surgical table may result in an abrupt patient displacement during surgery. Serious or critical adverse health consequences may occur, including traumatic injury, airway compromise, and surgical procedure complications, among others. Baxter has received three complaints related to this issue, with no reported patient injury. |
| Nov 11 |
Class II |
Baxter Healthcare Corporation Device |
Operating table column TS7500 MOBIUS, Hybrid operating table column, Model/Catalog Number: 1704695 There is an issue with the main lift mechanism. The main lift may unexpectedly drop from its set position to its lowest position during use. In these cases, the tabletop could not be raised again after the drop occurred. The issue has been associated with unexpected wear of the main lift assembly, also known as the telescopic spindle. An uncontrolled drop of the surgical table may result in an abrupt patient displacement during surgery. Serious or critical adverse health consequences may occur, including traumatic injury, airway compromise, and surgical procedure complications, among others. Baxter has received three complaints related to this issue, with no reported patient injury. |
| Nov 11 |
Class II |
Baxter Healthcare Corporation Device |
TruSystem 7000 U Operating Table (dV), Product Code 1723633 The main lift may unexpectedly drop from its set position to its lowest position during use. The tabletop may not be able to be raised again after the drop occurs. An uncontrolled drop of the surgical table may result in an abrupt patient displacement during surgery. Serious or critical adverse health consequences may occur, including traumatic injury, airway compromise, and surgical procedure complications, among others. |
| Nov 11 |
Class II |
Baxter Healthcare Corporation Device |
Operating Table TruSystem 7000 U, Surgical table, universal, Model/Catalog Number: 1604788 There is an issue with the main lift mechanism. The main lift may unexpectedly drop from its set position to its lowest position during use. In these cases, the tabletop could not be raised again after the drop occurred. The issue has been associated with unexpected wear of the main lift assembly, also known as the telescopic spindle. An uncontrolled drop of the surgical table may result in an abrupt patient displacement during surgery. Serious or critical adverse health consequences may occur, including traumatic injury, airway compromise, and surgical procedure complications, among others. Baxter has received three complaints related to this issue, with no reported patient injury. |
| Nov 11 |
Class II |
Baxter Healthcare Corporation Device |
Mobile column TruSystem 7500 U, Product Code 1730720 The main lift may unexpectedly drop from its set position to its lowest position during use. The tabletop may not be able to be raised again after the drop occurs. An uncontrolled drop of the surgical table may result in an abrupt patient displacement during surgery. Serious or critical adverse health consequences may occur, including traumatic injury, airway compromise, and surgical procedure complications, among others. |
| Nov 11 |
Class II |
Baxter Healthcare Corporation Device |
TruSystem 7500 surgical table, Model/Catalog Number: 4091000 There is an issue with the main lift mechanism. The main lift may unexpectedly drop from its set position to its lowest position during use. In these cases, the tabletop could not be raised again after the drop occurred. The issue has been associated with unexpected wear of the main lift assembly, also known as the telescopic spindle. An uncontrolled drop of the surgical table may result in an abrupt patient displacement during surgery. Serious or critical adverse health consequences may occur, including traumatic injury, airway compromise, and surgical procedure complications, among others. Baxter has received three complaints related to this issue, with no reported patient injury. |
| Oct 21 |
Class II |
Baxter Healthcare Corporation Device |
Likorall Overhead Lifts Product Code: 3121001 Product Description: LIKORALL 200 Product Code: 3122005 Product Description: LIKORALL 242 ES, NATURAL Product Code: 3122005NA Product Description: LIKORALL 242 ES… Potential issue involving motor shaft breakage combined with reduced performance of the Single Fault Safety (SFS) system may lead to instances where the lift strap lowers more quickly than expected during use. Patients are at some risk for injury if a significant fall/drop were to occur due to this issue. |
| Sep 30 |
Class II |
Baxter Healthcare Corporation Device |
PRO+ 40" MRS SURFACE, mattress with Advanced Microclimate Technology (AMT) uses a non-powered system of intake and output valves to provide weight-based pressure redistribution whenever a patient moves or is repositioned… There is an error in the product description on the Unique Device Identification (UDI) label. These discrepancies in labeling do not align with the approved product or product specifications and may lead to incorrect product identification or selection, potentially resulting in use with an incompatible bed frame. |
| Sep 30 |
Class II |
Baxter Healthcare Corporation Device |
Brand Name: VOLARA System Product Name: VOLARA, HC, NA A Model/Catalog Number: M08594A Software Version: N/A Product Description: VOLARA, HOMECARE, NORTH AMERICA Component: No Contamination within the release test equipment flow path could have affected the accuracy of the nebulizer flow rate. Affected devices returned to firm and testing confirmed devices meet specifications. |
| Sep 30 |
Class II |
Baxter Healthcare Corporation Device |
PRO+ MRS SURFACE FOR VERSACARE, mattress with Advanced Microclimate Technology (AMT) uses a non-powered system of intake and output valves to provide weight-based pressure redistribution whenever a patient moves or is re… There is an error in the product description on the Unique Device Identification (UDI) label. These discrepancies in labeling do not align with the approved product or product specifications and may lead to incorrect product identification or selection, potentially resulting in use with an incompatible bed frame. |
| Sep 30 |
Class II |
Baxter Healthcare Corporation Device |
PRO+ 36" MRS SURFACE, mattress with Advanced Microclimate Technology (AMT) uses a non-powered system of intake and output valves to provide weight-based pressure redistribution whenever a patient moves or is repositioned… There is an error in the product description on the Unique Device Identification (UDI) label. These discrepancies in labeling do not align with the approved product or product specifications and may lead to incorrect product identification or selection, potentially resulting in use with an incompatible bed frame. |
| Sep 16 |
Class I |
Baxter Healthcare Corporation Drug |
Dextrose Injection, USP, 70 %, 2000 mL bags, Rx Only, Baxter Healthcare Corporation Deerfield, IL, 60016, Made in USA, NDC 00338-0719-06 Presence of Particulate Matter: particulate matter identified as stainless steel particles in the solution. |
| Sep 9 |
Class II |
Baxter Healthcare Corporation Device |
Baxter Novum IQ Syringe Pump, Model Number 40800BAXUS A software issue that may occur during a Volume/Time (VOT) multi-syringe infusion when a syringe reaches empty and is replaced while a Volume To Be Infused (VTBI) remains. |
| Sep 9 |
Class II |
Baxter Healthcare Corporation Device |
Baxter Novum IQ Syringe Pump, Loaner, Model Number 40800BAXUSL A software issue that may occur during a Volume/Time (VOT) multi-syringe infusion when a syringe reaches empty and is replaced while a Volume To Be Infused (VTBI) remains. |
| Sep 9 |
Class II |
Baxter Healthcare Corporation Drug |
Clindamycin Injection USP in 5% Dextrose, 900 mg per 50 mL (12 mg/mL) in GALAXY 50 mL Single Dose Container, Rx only, Sterile Nonpyrogenic, Baxter Healthcare Corporation, Deerfield, IL 60015 USA, NDC 0338-3814-50. CGMP Deviations |
| Sep 9 |
Class II |
Baxter Healthcare Corporation Drug |
Vasopressin, in 0.9% Sodium Chloride Injection, 20 units per 100 mL (0.2 units/mL), 100mL Single-Dose Container, Rx only, Sterile, Baxter Healthcare Corporation, Deerfield, IL, 60012 USA, NDC 0338-9640-12. CGMP Deviations |
| Sep 9 |
Class II |
Baxter Healthcare Corporation Drug |
Daptomycin, in 0.9% Sodium Chloride Injection, 1,000 mg per 100 mL (10 mg/mL), 1,000 mg total, in 1000 mL Single Dose Container, Rx only, Sterile Nonpyrogenic, Baxter Healthcare Corporation, Deerfield, IL 60015 USA, NDC … CGMP Deviations |
| Sep 9 |
Class II |
Baxter Healthcare Corporation Drug |
CARDENE IV (Nicardipine Hydrochloride) in 0.83% Sodium Chloride Injection, 40 mg in 200 mL (0.2 mg/mL) in GALAXY Single-Dose Container, Manufactured and Marketed by: Baxter Healthcare Corporation, Deerfield, IL 60015 USA… CGMP Deviations |
| Sep 9 |
Class I |
Baxter Healthcare Corporation Drug |
0.9% Sodium Chloride Injection USP 500 mL, VIAFLEX Plastic Containers, with 24 units per case. Baxter Healthcare Corporation, Deerfield, IL, 60015, USA, Made in USA, NDC 0338-0049-03 Presence of particulate matter: Particulates identified as fiberglass |