Company record
GE MEDICAL SYSTEMS ISRAEL, FUNCTIONAL IMAGING
0 FDA warning letters since 2023 and 5 recalls in the last 12 months.
Get an email the day FDA posts anything new about GE MEDICAL SYSTEMS ISRAEL, FUNCTIONAL IMAGING.
Recalls
| Reported | Class | Firm | Product and reason |
|---|---|---|---|
| Jan 28 | Class II | GE MEDICAL SYSTEMS ISRAEL, FUNCTIONAL IMAGING Device |
GE Healthcare Omni Legend, sold under the following names: OMNI Legend 16, Omni Legend 21, OMNI Legend 32, Omni Legend PET Gantry 16cm - MEA, Omni Legend PET Gantry 16cm Haifa LM, Omni Legend PET Gantry 16cm Mobile, O… There is a potential intermittent issue on certain Omni Legend systems that can result in a streaking artifact in the PET clinical scan images. This streaking artifact is most easily identified in transaxial slices on the acquisition console (both corrected and non-corrected for attenuation). FDA notice Z-1112-2026 |
| Jan 21 | Class II | GE MEDICAL SYSTEMS ISRAEL, FUNCTIONAL IMAGING Device |
SMV DSI, System, Tomography, Computed, Emission GE HealthCare has become aware that certain Nuclear Medicine systems that are past the End of Guaranteed Service (herein referred to as Impacted Systems and listed in the Affected Product Details section of this letter) could have been transported or relocated without adequate detector support. This could result in excessive stress being applied to the detector mounting mechanisms, compromising their integrity. If this occurs, it can potentially result in a detector fall and lead to life-threatening bodily injury. There have been no reports of detector falls or injuries as a result of this potential issue. The Impacted Systems affected by this notice are those that have not been manufactured for several years. GE HealthCare has previously communicated End of Guaranteed Service for these Impacted Systems. FDA notice Z-1045-2026 |
| Jan 21 | Class II | GE MEDICAL SYSTEMS ISRAEL, FUNCTIONAL IMAGING Device |
SMV BodyTrack, System, Tomography, Computed, Emission GE HealthCare has become aware that certain Nuclear Medicine systems that are past the End of Guaranteed Service (herein referred to as Impacted Systems and listed in the Affected Product Details section of this letter) could have been transported or relocated without adequate detector support. This could result in excessive stress being applied to the detector mounting mechanisms, compromising their integrity. If this occurs, it can potentially result in a detector fall and lead to life-threatening bodily injury. There have been no reports of detector falls or injuries as a result of this potential issue. The Impacted Systems affected by this notice are those that have not been manufactured for several years. GE HealthCare has previously communicated End of Guaranteed Service for these Impacted Systems. FDA notice Z-1046-2026 |
| Jan 21 | Class II | GE MEDICAL SYSTEMS ISRAEL, FUNCTIONAL IMAGING Device |
SMV DSX New Line, System, Tomography, Computed, Emission GE HealthCare has become aware that certain Nuclear Medicine systems that are past the End of Guaranteed Service (herein referred to as Impacted Systems and listed in the Affected Product Details section of this letter) could have been transported or relocated without adequate detector support. This could result in excessive stress being applied to the detector mounting mechanisms, compromising their integrity. If this occurs, it can potentially result in a detector fall and lead to life-threatening bodily injury. There have been no reports of detector falls or injuries as a result of this potential issue. The Impacted Systems affected by this notice are those that have not been manufactured for several years. GE HealthCare has previously communicated End of Guaranteed Service for these Impacted Systems. FDA notice Z-1044-2026 |
| Jan 21 | Class II | GE MEDICAL SYSTEMS ISRAEL, FUNCTIONAL IMAGING Device |
MAXXUS, System, Tomography, Computed, Emission GE HealthCare has become aware that certain Nuclear Medicine systems that are past the End of Guaranteed Service (herein referred to as Impacted Systems and listed in the Affected Product Details section of this letter) could have been transported or relocated without adequate detector support. This could result in excessive stress being applied to the detector mounting mechanisms, compromising their integrity. If this occurs, it can potentially result in a detector fall and lead to life-threatening bodily injury. There have been no reports of detector falls or injuries as a result of this potential issue. The Impacted Systems affected by this notice are those that have not been manufactured for several years. GE HealthCare has previously communicated End of Guaranteed Service for these Impacted Systems. FDA notice Z-1047-2026 |