Recalls
When a product is unsafe or breaks the rules, the company pulls it back and FDA classes the recall. Class I could cause serious harm or death. Class II could cause temporary harm. Class III is unlikely to hurt anyone.
5,412 recalls in the last 12 months. Newest first.
| Reported | Class | Firm | Product and reason |
|---|---|---|---|
| Mar 18 | Class II | Beckman Coulter Mishima K.K. Device |
DxC 700 AU, REF: B86444, B86446 A delay in results may occur. When clinical chemistry analyzer calibration monitor with PC installed with Microsoft SQL Server 2022 Express is open beyond15 minutes may lead to: Reagent Blank and calibration databases not opening errors: CAL History DB Open Error.., RB History DB Open Error..; system will stop analyzing, firm service must visit to apply software solution; may lead to delay in diagnosis and/or patient treatment. FDA notice Z-1552-2026 |
| Mar 18 | Class II | Instrumentation Laboratory Device |
GEM Premier 5000 PAK; Part No. 00055360011. Confirmed customer complaints indicating that GEM PAKs (cartridges) for the GEM Premier 5000 may experience an increased incidence of Process Control Solution Not Detected (PCSND) errors during warm-up, including consecutive occurrences, resulting in GEM PAK ejection and requiring insertion of a new GEM PAK. iQM2 is an active quality process control program designed to provide continuous monitoring of the entire testing process. Thus, if a GEM PAK completes AutoPAK Validation following warm-up, it may remain in use. Consecutive GEM PAK ejections during warm-up may prolong turnaround times, potentially delaying results. In such cases, patient management may require reassessment once results are available. While many GEM PAKs continue to perform as intended, consecutive ejections may increase the likelihood of operational disruption, highlighting the importance of advance planning where feasible to help minimize impact. FDA notice Z-1527-2026 |
| Mar 18 | Class III | Penner Patient Care, Inc. Device |
Penner Pacific Bathing Spa, Model Numbers 360030-1C, 360030-1CE, 360030-1CTS, 360030-XCE, 360030-XC, 360030-1CT, 360030-1C, 360030-XC, 360030-XCT, 360030-1CTS, 360030-XCTS, 3600301-CTS, 360030-XCE, 360030-1CT, 360030-1CE… The device does not bear a unique device identifier. FDA notice Z-1503-2026 |
| Mar 18 | Class III | Penner Patient Care, Inc. Device |
Penner Pacific Bathing Spa, Model Numbers 360020-1EP The device does not bear a unique device identifier. FDA notice Z-1501-2026 |
| Mar 18 | Class II | Exactech, Inc. Device |
Brand Name: Equinoxe Ergo Product Name: Ergo Modular Impactor Handle Model/Catalog Number: 321-09-05 Impactor handle may be missing cross-pin FDA notice Z-1509-2026 |
| Mar 18 | Class II | Medline Industries, LP Device |
Medline Kits containing Cardinal Health s Aqua-Seal Chest Drainage Unit: 1) OPEN HEART, Model Number: DYNJ902487A; 2) CARDIAC PROCEDURE, Model Number: DYNJ908126; 3) CARDIO CONGENITO, Model Number: DYNJ910851 The instructions for use (IFUs) on specified Cardinal Health Chest Drainage Units (CDUs) and accessories have been updated to clarify the intended target patient population as adults, 18 years and older. FDA notice Z-1562-2026 |
| Mar 18 | Class II | Instrumentation Laboratory Device |
GEM Premier 5000 PAK; Part No. 00055407511. Confirmed customer complaints indicating that GEM PAKs (cartridges) for the GEM Premier 5000 may experience an increased incidence of Process Control Solution Not Detected (PCSND) errors during warm-up, including consecutive occurrences, resulting in GEM PAK ejection and requiring insertion of a new GEM PAK. iQM2 is an active quality process control program designed to provide continuous monitoring of the entire testing process. Thus, if a GEM PAK completes AutoPAK Validation following warm-up, it may remain in use. Consecutive GEM PAK ejections during warm-up may prolong turnaround times, potentially delaying results. In such cases, patient management may require reassessment once results are available. While many GEM PAKs continue to perform as intended, consecutive ejections may increase the likelihood of operational disruption, highlighting the importance of advance planning where feasible to help minimize impact. FDA notice Z-1531-2026 |
| Mar 18 | Class II | Instrumentation Laboratory Device |
GEM Premier 5000; Part No. 00055415008. Confirmed customer complaints indicating that GEM PAKs (cartridges) for the GEM Premier 5000 may experience an increased incidence of Process Control Solution Not Detected (PCSND) errors during warm-up, including consecutive occurrences, resulting in GEM PAK ejection and requiring insertion of a new GEM PAK. iQM2 is an active quality process control program designed to provide continuous monitoring of the entire testing process. Thus, if a GEM PAK completes AutoPAK Validation following warm-up, it may remain in use. Consecutive GEM PAK ejections during warm-up may prolong turnaround times, potentially delaying results. In such cases, patient management may require reassessment once results are available. While many GEM PAKs continue to perform as intended, consecutive ejections may increase the likelihood of operational disruption, highlighting the importance of advance planning where feasible to help minimize impact. FDA notice Z-1534-2026 |
| Mar 18 | Class II | Waldemar Link GmbH & Co. KG (Mfg Site) Device |
Endo-Model Replacement Plateau; Item Number: 15-8521/15; The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. FDA notice Z-1520-2026 |
| Mar 18 | Class II | Instrumentation Laboratory Device |
GEM Premier 5000; Part No. 00055430008. Confirmed customer complaints indicating that GEM PAKs (cartridges) for the GEM Premier 5000 may experience an increased incidence of Process Control Solution Not Detected (PCSND) errors during warm-up, including consecutive occurrences, resulting in GEM PAK ejection and requiring insertion of a new GEM PAK. iQM2 is an active quality process control program designed to provide continuous monitoring of the entire testing process. Thus, if a GEM PAK completes AutoPAK Validation following warm-up, it may remain in use. Consecutive GEM PAK ejections during warm-up may prolong turnaround times, potentially delaying results. In such cases, patient management may require reassessment once results are available. While many GEM PAKs continue to perform as intended, consecutive ejections may increase the likelihood of operational disruption, highlighting the importance of advance planning where feasible to help minimize impact. FDA notice Z-1538-2026 |
| Mar 18 | Class II | Instrumentation Laboratory Device |
GEM Premier 5000; Model No. 00055430010. Confirmed customer complaints indicating that GEM PAKs (cartridges) for the GEM Premier 5000 may experience an increased incidence of Process Control Solution Not Detected (PCSND) errors during warm-up, including consecutive occurrences, resulting in GEM PAK ejection and requiring insertion of a new GEM PAK. iQM2 is an active quality process control program designed to provide continuous monitoring of the entire testing process. Thus, if a GEM PAK completes AutoPAK Validation following warm-up, it may remain in use. Consecutive GEM PAK ejections during warm-up may prolong turnaround times, potentially delaying results. In such cases, patient management may require reassessment once results are available. While many GEM PAKs continue to perform as intended, consecutive ejections may increase the likelihood of operational disruption, highlighting the importance of advance planning where feasible to help minimize impact. FDA notice Z-1539-2026 |
| Mar 18 | Class II | Raz Design Inc Device |
Raz-AT (Attendant Tilt) Mobile Shower Commode Chair, Catalog Number Z300 UDI-DI code: (01)00628758003007 Raz-ART (Attendant Rotational Tilt) Mobile Shower Commode Chair, Catalog Number Z333 UDI-DI code: (01)00628758… Due to a modification by a vendor and may be reinstalled without properly engaging the outside rear seat brackets that are used to keep the seat in place. FDA notice Z-1498-2026 |
| Mar 18 | Class II | Waldemar Link GmbH & Co. KG (Mfg Site) Device |
Endo-Model SL Connection Component incl. PE-Plateau; Item Number: 16-2840/05; The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. FDA notice Z-1511-2026 |
| Mar 18 | Class I | Trividia Health, Inc. Device |
Owner's Booklets and Instructions for Use that are used with the following blood glucose measuring devices. Description/Item: Walgreens TRUE METRIX AIR Kit/REA4001-01, Leader TRUE METRIX AIR Kit/REA4002-01, CVS TRUE … The system labeling (user manual and online labeling) did not provide adequate directions for lay users to act on the E-5 error code. The error code description and recommended actions for the E-5 error code in the labeling do not: (a) clearly emphasize that an E-5 error code could represent a very high blood glucose level, and (b) prominently convey the appropriate immediate actions, such as contacting a healthcare professional. This could lead to a delay in treatment if the user does not seek medical attention immediately when receiving an E-5 error code and experiencing symptoms of high glucose. FDA notice Z-1547-2026 |
| Mar 18 | Class II | Waldemar Link GmbH & Co. KG (Mfg Site) Device |
Endo-Model Replacement Plateau; Item Number: 15-8030/12; The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. FDA notice Z-1517-2026 |
| Mar 18 | Class II | Instrumentation Laboratory Device |
GEM Premier 5000; Part No. 00055415005. Confirmed customer complaints indicating that GEM PAKs (cartridges) for the GEM Premier 5000 may experience an increased incidence of Process Control Solution Not Detected (PCSND) errors during warm-up, including consecutive occurrences, resulting in GEM PAK ejection and requiring insertion of a new GEM PAK. iQM2 is an active quality process control program designed to provide continuous monitoring of the entire testing process. Thus, if a GEM PAK completes AutoPAK Validation following warm-up, it may remain in use. Consecutive GEM PAK ejections during warm-up may prolong turnaround times, potentially delaying results. In such cases, patient management may require reassessment once results are available. While many GEM PAKs continue to perform as intended, consecutive ejections may increase the likelihood of operational disruption, highlighting the importance of advance planning where feasible to help minimize impact. FDA notice Z-1533-2026 |
| Mar 18 | Class II | International Life Sciences Device |
Artelon FlexBand Dynamic Matrix Ref: 31057 Augmentation devices failed bacterial endotoxin testing. FDA notice Z-1554-2026 |
| Mar 18 | Class I | Trividia Health, Inc. Device |
Owner's Booklets and Instructions for Use that are used with the following blood glucose measurement devices. Description/Item: TRUE METRIX PRO Meter Only/RE4H01P-40, TRUE METRIX PRO Starter Kit/RE4H01P-43, PROCURE T… The system labeling (user manual and online labeling) did not provide adequate directions for lay users to act on the E-5 error code. The error code description and recommended actions for the E-5 error code in the labeling do not: (a) clearly emphasize that an E-5 error code could represent a very high blood glucose level, and (b) prominently convey the appropriate immediate actions, such as contacting a healthcare professional. This could lead to a delay in treatment if the user does not seek medical attention immediately when receiving an E-5 error code and experiencing symptoms of high glucose. FDA notice Z-1546-2026 |
| Mar 18 | Class II | Beckman Coulter Mishima K.K. Device |
CHEMISTRY ANALYZER AU5800, REF: B96697, B96698, B23279, B23280, B23281 A delay in results may occur. When clinical chemistry analyzer calibration monitor with PC installed with Microsoft SQL Server 2022 Express is open beyond15 minutes may lead to: Reagent Blank and calibration databases not opening errors: CAL History DB Open Error.., RB History DB Open Error..; system will stop analyzing, firm service must visit to apply software solution; may lead to delay in diagnosis and/or patient treatment FDA notice Z-1553-2026 |
| Mar 18 | Class II | Instrumentation Laboratory Device |
GEM Premier 5000 PAK, Part No. 00055360004. Confirmed customer complaints indicating that GEM PAKs (cartridges) for the GEM Premier 5000 may experience an increased incidence of Process Control Solution Not Detected (PCSND) errors during warm-up, including consecutive occurrences, resulting in GEM PAK ejection and requiring insertion of a new GEM PAK. iQM2 is an active quality process control program designed to provide continuous monitoring of the entire testing process. Thus, if a GEM PAK completes AutoPAK Validation following warm-up, it may remain in use. Consecutive GEM PAK ejections during warm-up may prolong turnaround times, potentially delaying results. In such cases, patient management may require reassessment once results are available. While many GEM PAKs continue to perform as intended, consecutive ejections may increase the likelihood of operational disruption, highlighting the importance of advance planning where feasible to help minimize impact. FDA notice Z-1524-2026 |
| Mar 18 | Class III | Penner Patient Care, Inc. Device |
Penner Pacific Bathing Spa, Model Numbers 360020-1P The device does not bear a unique device identifier. FDA notice Z-1502-2026 |
| Mar 18 | Class II | Waldemar Link GmbH & Co. KG (Mfg Site) Device |
Endo-Model Replacement Plateau; Item Number: 15-0027/11; The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. FDA notice Z-1521-2026 |
| Mar 11 | Class II | Bader Enterprises, Inc. Food |
Premium Food Bubble Gum, packed in 2.5 oz clear flexible plastic packaging, all lots and codes. Sold in unit case of 30 LB. Contains undeclared colors (FD&C Blue 1 Lake and FD&C Blue 2 Lake). FDA notice H-0539-2026 |
| Mar 11 | Class I | Perfect Pasta, Incorporated Food |
Lobster & Crab Ravioli. Keep Frozen. Contains: Wheat, Eggs, Milk, Crustaceans-Shellfish. Product is intended to be further cooked. Weight: 1-10 pound (4.5g). Use within 6 months. 801-541-9292-www.FunarosPerfectPasta.co… Undeclared shrimp, crab, lobster, pollock (fish), whiting (fish), and soy. FDA notice H-0620-2026 |
| Mar 11 | Class II | Bader Enterprises, Inc. Food |
Premium Food Jordan Almonds, packed in 2.0 oz and 3.5 oz clear flexible plastic packaging. Contains undeclared allergen (wheat) and colors (FD&C Blue 1 Lake and FD&C Blue 2 Lake). FDA notice H-0538-2026 |
| Mar 11 | Class I | Karns Prime And Fancy Foods Food |
Karns Foods, Mini Dark Chocolate Raspberry Cups, 8 oz Clear plastic tamper evident packs, 36-42 packed per breakout Product may contain undeclared peanuts. FDA notice H-0574-2026 |
| Mar 11 | Class II | Italianway Import, Inc. Food |
VERGANI 1944 MILANO 'PANDORO CLASSICO' Gluten Free, 600g NET WT. 1 LBS. 5.2 OZ., packaged in paper cartons, 6 units per case. Lot 217666, UPC 8002114019833 Potential contamination with foreign material (Teflon fragments) from flaking cooking molds. FDA notice H-0540-2026 |
| Mar 11 | Class I | Juniper Granola, LLC Food |
Junebar Peanut Chocolate Chip All Natural Snack Bar; INGREDIENTS: ORGANIC PEANUT BUTTER, DATE PASTE, ORGANIC BLACK BEANS, ORGANIC SWEET POTATOES, GLUTEN FREE ROLLED OATS, SEMI-SWEET SOY FREE VEGAN SHOCOLATE CHIPS (ORGANI… Products contain undeclared milk and soy. FDA notice H-0542-2026 |
| Mar 11 | Class II | IF Holding II, LLC Food |
tippy toes apple pear banana 6 months & up baby food 2-4OZ (113g) PACKS NET WT 8 OZ (226g) DISTRIBUTED BY TOPCO ASSOCIATES LLC ELK GROVE VILLAGE, IL 60007 1-888-423-0139 PRODUCT OF USA UPC: 036800265783 Potential contamination with patulin. FDA notice H-0544-2026 |
| Mar 11 | Class I | Juniper Granola, LLC Food |
Junebar Chocolate Cherry All Natural Snack Bar; INGREDIENTS: ORGANIC ALMOND BUTTER, DATE PASTE, ORGANIC BLACK BEANS, ORGANIC SWEET POTATOES, GLUTEN FREE ROLLED OATS, SEMI-SWEET SOY FREE VEGAN CHOCOLATE CHIPS (ORGANIC CAN… Products contain undeclared milk and soy. FDA notice H-0543-2026 |
| Mar 11 | Class I | ANTHONY TRINH, 123Herbals LLC Drug |
SILINTAN 25/pills, packaged in a 25-count bottle, Shanghai Chinese Medical Works, Shanghai, China Marketed Without an Approved NDA/ANDA: FDA analysis revealed the presence of undeclared meloxicam. FDA notice D-0388-2026 |
| Mar 11 | Class II | ACME UNITED CORPORATION Drug |
Children's Healthcare of Atlanta, Instant Hand Sanitizing Wipe(Benzalkonium Chloride 0.13%), 1000 per case, Made in USA for Food Service Resources, Flowery Branch, GA 30542, NDC 0924-7130-00 CGMP Deviations FDA notice D-0377-2026 |
| Mar 11 | Class II | Teva Pharmaceuticals USA, Inc Drug |
Metoprolol Succinate Extended-Release Tablets, Rx Only, 100 mg, 100 tablets bottles (NDC: 45963-677-11) and 1,000 tablets bottles (NDC: 45963-677-96), Teva Pharmaceuticals, Parsippany, NJ 07054. Failed Dissolution Specifications FDA notice D-0356-2026 |
| Mar 11 | Class II | ACME UNITED CORPORATION Drug |
1) BZK Antiseptic Towelettes (Benzalkonium Chloride 0.13%) 5"x7" Piedmont Sanitizing Hand Wipes, 1,000 ea Bulk, Made in USA for: Food Service Resources, Flowery Branch, GA 30542, NDC 0924-7130-00. 2) BZK Antiseptic Tow… CGMP Deviations FDA notice D-0362-2026 |
| Mar 11 | Class II | ACME UNITED CORPORATION Drug |
WP WipesPlus Hand Sanitizing Wipes (Benzalkonium Chloride 0.13%), 5x7, 100 CT, Progressive Products, 211 S. Ridge Street, Rye Brook, NY 10573. NDC 67151-727-01. CGMP Deviations FDA notice D-0372-2026 |
| Mar 11 | Class II | ACME UNITED CORPORATION Drug |
Cleansing Towelette (Benzalkonium Chloride 0.13%), 5"x 7", 1,000 case/Bulk, Med-Nap, Brooksville, FL 34601, Made in USA, NDC 0924-0243-00. CGMP Deviations FDA notice D-0370-2026 |
| Mar 11 | Class II | Teva Pharmaceuticals USA, Inc Drug |
Metoprolol Succinate Extended-Release Tablets, 200 mg, 100 tablets bottles, Rx Only, Teva Pharmaceuticals, Parsippany, NJ 07054, NDC: 45963-678-11 Failed Dissolution Specifications FDA notice D-0357-2026 |
| Mar 11 | Class II | ACME UNITED CORPORATION Drug |
Green Guard Antiseptic Wipes (Benzalkonium Chloride 0.13%), 25 wipes per box, Distributed by Green Guard, St. Louis, MO 63045, NDC 47682-056-73 CGMP Deviations FDA notice D-0374-2026 |
| Mar 11 | Class II | Teva Pharmaceuticals USA, Inc Drug |
Metoprolol Succinate Extended-Release Tablets, 25 mg, 100 tablets bottles (NDC: 45963-709-11) and 1,000 tablets bottles (NDC: 45963-709-96), Rx Only, Teva Pharmaceuticals, Parsippany, NJ 07054 Failed Dissolution Specifications FDA notice D-0354-2026 |
| Mar 11 | Class II | Radnostix Drug |
Sodium Iodide (I-131) Solution, Therapeutic Oral, packaged as a) 1 ml V-vial, NDC 69208-003-15; Order 49317, 49323, 49325, 49329, 49333, 49339, 49341,49355, 49364, 49380, 49392. (b) 2 ml V-Vial, NDC 69208-003-25; Order … Presence of Particulate Matter: Due to production issues FDA notice D-0389-2026 |
| Mar 11 | Class II | MYLAN PHARMACEUTICALS INC Drug |
Amnesteem (Isotretinoin) Capsules, USP 40 mg, packaged in 3 x 10-Count Prescription Packs, Rx Only, Manufactured for: Mylan Pharmaceuticals Inc., Morgantown, WV, 26505 USA, Made in France, NDC 0378-6614-93. Failed Dissolution Specifications FDA notice D-0399-2026 |
| Mar 11 | Class I | StuffbyNainax Drug |
MR. 7 SUPER 700000 capsules, 1 capsule blister card, Distributed by mR. 7 Marketed Without an Approved NDA/ANDA: FDA analysis revealed the presence of undeclared sildenafil and tadalafil FDA notice D-0397-2026 |
| Mar 11 | Class III | Cipla USA, Inc. Drug |
Nilotinib Capsules, 200 mg per capsule, packaged in cartons, Rx only, Manufactured for: Cipla USA, Inc., 10 Independence Boulevard, Suite 300, Warren, NJ 07059, Outer carton: 112 capsules (4 individual packs containing 2… Failed Tablet/Capsule Specifications: Observed OOS results at 6-months long-term stability condition for Description test and Appearance by Visual Inspection test. FDA notice D-0382-2026 |
| Mar 11 | Class II | Harbin Jixianglong Biotech Co., Ltd. Drug |
Semaglutide, For Rx compounding use only, packaged in a) 1g, NDC 84385-106-01; b) 5g, NDC 84385-106-02; c) 10g, NDC 84385-106-06; d) 25g, NDC 84385-106-03; d) 50g, NDC 84385-106-04 Manufacturer: Harbin Jixianglong Biotec… CGMP Deviations This recall has been initiated due to failing to complete process validation and bacterial endotoxin method validation before distribution FDA notice D-0379-2026 |
| Mar 11 | Class II | ACME UNITED CORPORATION Drug |
Dukal BZK Antiseptic Towelette (Benzalkonium Chloride 0.13%) 1000 Packs per case, Manufactured For: Dukal, LLC, Ronkonkoma, NY 11779, Made in USA, NDC 65517-0004-1 CGMP Deviations FDA notice D-0360-2026 |
| Mar 11 | Class II | ACME UNITED CORPORATION Drug |
Medi-First Antiseptic Wipes (BZK)(Benzalkonium Chloride 0.13%), 100 wipes per box, Manufactured for Medique Products, Fort Meyers, FL, 33967, NDC 47682-122-33. CGMP Deviations FDA notice D-0365-2026 |
| Mar 11 | Class II | ACME UNITED CORPORATION Drug |
Max Packaging Antibacterial Towelette (Benzalkonium Chloride 0.13%), 1 towelette, 4x7, Max Packaging, Made in the USA, NDC 59647-750-01 CGMP Deviations FDA notice D-0363-2026 |
| Mar 11 | Class II | ACME UNITED CORPORATION Drug |
Antimicrobial Alcohol Hand Wipe, Isopropyl Alcohol 70%, Manufactured for : Custom Packaging Co., Inc, Louisville, KY 4023, NDC 0924-251-00. CGMP Deviations FDA notice D-0378-2026 |
| Mar 11 | Class II | Teva Pharmaceuticals USA, Inc Drug |
Metoprolol Succinate Extended-Release Tablets, 50 mg, 100 tablets bottles (NDC: 45963-676-11) and 1,000 tablets bottles (NDC: 45963-676-96), Rx Only, Teva Pharmaceuticals, Parsippany, NJ 07054 Failed Dissolution Specifications FDA notice D-0355-2026 |
| Mar 11 | Class II | ACME UNITED CORPORATION Drug |
Dynarex, BZK Antiseptic Towelettes (Benzalkonium Chloride 0.13%), 100 packets, 5x7, Manufactured for Dynarex Corporation, 10 Glenshaw Street, Orangeburg, NY 10962,USA, NDC 67777-245-01 CGMP Deviations FDA notice D-0375-2026 |